Ipmux-1 e1/t1 configuration, E1 configuration, E.4 ipmux-1 e1/t1 configuration – RAD Data comm IPmux-1 User Manual
Page 112
Appendix E Parameters and Screens
IPmux-1/1E Installation and Operation Manual
E-14
IPmux-1 E1/T1 Configuration
➤
To overwrite the system and reconfigure it according to default settings:
• Type Y.
IPmux-1 is reconfigured according to default settings. Following this,
IPmux-1 performs an automatic Reset.
OR
• Type N to exit and return to the General Configuration menu.
1. Setting default parameters from an ASCII terminal erases all the configurations
and optionally asks if you want to erase Host IP and Default Gateway
Configuration.
2. Setting default parameters from Telnet or NMS does not erase the Host IP or
Default Gateway Configuration.
E.4 IPmux-1 E1/T1 Configuration
E1 Configuration
E1 CONFIGURATION
1. Channel Status
Enable
2. Transmit Clock Source
Adaptive
3. Loopback State
Disable
4. Rx. Sensitivity
-10dB
5. Line Type
CRC4 enable
6. Idle Code
7E
7. Signaling Mode
CAS enable
8. Cond. Data pattern
FF
9. Cond. CAS (ABCD)pattern
01
ESC. Exit
Select item from the menu.
Use
Figure E-19. E1 Physical Layer Configuration Menu
When “unframed” mode is selected, the Idle Code, Signaling Mode, Cond Data
Pattern and Cond CAS Pattern fields are not present.
When CAS Disabled is selected, the Cond CAS Pattern field is not present.
Note