Ascii terminal configuration – RAD Data comm IPmux-1 User Manual
Page 108
Appendix E Parameters and Screens
IPmux-1/1E Installation and Operation Manual
E-10 General
Configuration
The other alarms are not used.
ASCII Terminal Configuration
ASCII TERMINAL CONFIGURATION
1. Display Mode Color
2. Baud Rate (bps) 19200
3. Change Password
4. 15 Min. Timeout On
ESC. Exit
NOTICE: Change the Baud Rate of the ASCII terminal after
changing and saving of new Baud Rate data !
Select item from the menu:_
Use
Figure E-13. ASCII Terminal Configuration Menu
Table E-6. ASCII Terminal Configuration Parameters
Name Possible
Values Remarks
Display Mode
Color
MonoChrome 3 color
MonoChrome 2 color
Baud Rate
9600, 19200, 38400, 57600,
115200
– in units of bps
Default: 19200 bps
Change Password
Choose this option to enter a menu that allows the
user to change the current password
15 Min. Timeout
On, Off
On – terminal/Telnet exits to the password screen if
no characters are sent by the terminal for
15 minutes
Main Menu
↓
2. Configuration
↓
1. General
Configuration
↓
4. ASCII
Terminal Config