IPmux-1/1E Installation and Operation Manual

Chapter 1 Introduction

Technical Specifications

1-27

Signal Levels


Jitter Performance

Receive: 0 to –10 dB
Transmit: ±2.7V ± 10%, adjustable, measured in range

0 to 133 feet, without CSU
AT&T TR-62411, G.824 standards

Indicators

General:

PWR

ON when power supply is OK
OFF when a malfunction is detected

RDY

ON when self-test is successfully completed
OFF during self-test

BLINKS when self-test fails

Ethernet Port:

LINK

OFF when line is not active
ON when line is OK

ACT

OFF when no activity

ON when a frame is being transmitted or
received on the line

100M OFF when 10 MHz

ON when 100 MHz

FDX

OFF when half duplex
ON when full duplex

E1/T1 Port:

SYNC ON when the port is synchronized (no alarm)

OFF when signal loss, LOF or AIS is detected
(local alarm)

BLINKS when RDI is detected (remote alarm)

ISDN Port:

SYNC ON when the ISDN BRI frame is

synchronized (no alarm)
OFF when signal loss, LOF is detected

FXS Port:

SYNC ON when off-hook

OFF when on-hook
BLINKS when ringing

Note: All LEDs are green and ON after power-up.

Power


1 power supply

100 to 240 VAC, 50 or 60 Hz
–36 to –72 VDC (–48 VDC nominal)
Note: IPmux-1E only has AC power supply option.