Roland G-70 User Manual
Page 235
Appendix | MFX and IFX types and parameters
G-70 Music Workstation
r
235
● Chorus Pre Delay (0.0~100.0ms)—Adjusts the delay
between the incoming direct signal and the moment when
the chorus starts working.
● Chorus Rate (0.05~10.0Hz)—Frequency, i.e. modulation
● Chorus Depth (0~127)—Modulation intensity.
● Chorus Balance (D100:0W, D50:50W, D0:100W)—Vol-
ume balance between the direct sound (D) and the chorus
sound (W).
34. EH‰ Flanger
This effect connects an enhancer and a flanger in series.
● Enhancer Sens (0~127)—Sensitivity of the enhancer.
● Enhancer Mix Level (0~127)—Level of the overtones gen-
● Flanger Pre Delay (0.0~100.0ms)—Adjusts the delay time
from when the direct sound begins until the flanger sound
is heard.
● Flanger Rate (0.05~10.0Hz)—Frequency, i.e. modulation
● Flanger Depth (0~127)—Modulation intensity.
● Flanger Feedback (–98%~0~98%)—Adjusts the propor-
● Flanger Balance (D100:0W, D50:50W, D0:100W)—Vol-
ume balance between the direct sound (D) and the flanger
sound (W).
35. EH‰ Delay
This effect connects an enhancer and a delay in series.
● Enhancer Sens (0~127)—Sensitivity of the enhancer.
● Enhancer Mix Level (0~127)—Level of the overtones gen-
● Delay Time (0.0~500.0ms)—Adjusts the time until the
● Delay Feedback (–98%~0~98%)—Adjusts the amount of
the delay sound that’s fed back into the effect. Negative (–)
settings invert the phase.
● Delay HF Damp (200~8000Hz, Bypass)—Adjusts the fre-
● Delay Balance (D100:0W, D50:50W, D0:100W)—Adjusts
36. Chorus‰ DLY
This effect connects a chorus and a delay in series.
● Chorus Pre Delay (0.0~100.0ms)—Adjusts the delay
between the incoming direct signal and the moment when
the chorus starts working.
● Chorus Rate (0.05~10.0Hz)—Frequency, i.e. modulation
● Chorus Depth (0~127)—Modulation intensity.
● Chorus Balance (D100:0W, D50:50W, D0:100W)—Vol-
ume balance between the direct sound (D) and the chorus
sound (W).
● Delay Time (0.0~500.0ms)—Adjusts the time until the
● Delay Feedback (–98%~0~98%)—Adjusts the amount of
the delay sound that’s fed back into the effect. Negative (–)
settings invert the phase.
● Delay HF Damp (200~8000Hz, Bypass)—Adjusts the fre-
● Delay Balance (D100:0W, D50:50W, D0:100W)—Adjusts
37. Flanger‰ DLY
This effect connects a flanger and a delay in series.
● Flanger Pre Delay (0.0~100.0ms)—Adjusts the delay time
from when the direct sound begins until the flanger sound
is heard.
● Flanger Rate (0.05~10.0Hz)—Frequency, i.e. modulation
● Flanger Depth (0~127)—Modulation intensity.
● Flanger Feedback (–98%~0~98%)—Adjusts the propor-
● Flanger Balance (D100:0W, D50:50W, D0:100W)—Vol-
ume balance between the direct sound (D) and the flanger
sound (W).
● Delay Time (0.0~500.0ms)—Adjusts the time until the
● Delay Feedback (–98%~0~98%)—Adjusts the amount of
the delay sound that’s fed back into the effect. Negative (–)
settings invert the phase.
● Delay HF Damp (200~8000Hz, Bypass)—Adjusts the fre-
● Delay Balance (D100:0W, D50:50W, D0:100W)—Adjusts
38. CHO‰ Flanger
This effect connects a chorus and a flanger in series.
● Chorus Pre Delay (0.0~100.0ms)—Adjusts the delay
between the incoming direct signal and the moment when
the chorus starts working.
● Chorus Rate (0.05~10.0Hz)—Modulation frequency of the
chorus effect.
● Chorus Depth (0~127)—Modulation intensity of the cho-
rus effect.
● Chorus Balance (D100:0W, D50:50W, D0:100W)—Vol-
ume balance between the direct sound (D) and the chorus
sound (W).
● Flanger Pre Delay (0.0~100.0ms)—Adjusts the delay time
from when the direct sound begins until the flanger sound
is heard.
● Flanger Rate (0.05~10.0Hz)—Modulation frequency of
the flanger effect.
● Flanger Depth (0~127)—Modulation intensity of the
flanger effect.