Upgrading Your Server 9-11

When the hard disk drives are in the disk array configuration, you can restore the state before an
error using the auto-rebuild feature that stores the data in the old hard disk drive into a new one.

The auto-rebuild feature is available for the RAID1, RAID5, or RAID10 disk array configuration.

NOTE:

Onboard RAID controller (HostRAID) supports RAID levels

RAID0 and RAID1.

Auto-rebuild is carried out when you hot-swap a failed hard disk drive with a new one (replace the
disk while the server is powered). While auto-rebuild is in progress, the DISK LED flashes green
and amber alternatively to indicate it.

IMPORTANT:

„

When auto-rebuild fails, the DISK LED lights in amber. Remove
and install the hard disk drive again to restart auto-rebuild.

„

If the disk array monitoring utility is installed, it may display or act
as follows. If the DISK LED does not light in amber after auto-
rebuild, however, auto-rebuild has completed successfully.

– Displays "Rebuild was cancelled" on the screen while auto-

rebuild is in progress.

– Appears to stop and restart auto-rebuild.

Observe the following notes for auto-rebuild.

„

Do not power off the server in the period between a hard disk drive error and completion
of auto-rebuild.

„

When you removed a hard disk drive, wait at least 90 seconds before installing the hard
disk drive back again.

„

Do not replace another hard disk drive while rebuilding is in progress. (The DISK LED
flashes in green and amber alternatively while rebuilding the hard disk drive.)