8-6 Troubleshooting

Error
code

Error message

Recommended Action

02D1

System Memory exceeds the CPU's caching
limit.

02F4

EISA CMOS not write able.

02F5

DMA Test Failed.

02F6

Software NMI Failed.

02F7

Fail-safe Timer NMI Failed.

Contact your service representative.

0B22

Processors are installed out of order.

Request the maintenance to replace the CPU.

0B28

Unsupported Processor detected on
Processor 1.

0B29

Unsupported Processor detected on
Processor 2.

Make sure that the server supports the CPU.
If you are not sure, contact your service
representative to request the maintenance.

0B30

FAN1 Alarm occurred.

0B31

FAN2 Alarm occurred.

0B32

FAN3 Alarm occurred.

0B33

FAN4 Alarm occurred.

0B34

FAN5 Alarm occurred.

0B35

FAN6 Alarm occurred.

0B36

FAN7 Alarm occurred.

0B37

FAN8 Alarm occurred.

Contact your service representative to replace
the fan.

0B5F

Forced to use Processor with error

Because an error is detected in every CPU,
the system is forcibly started. Contact your
service representative.

0B60

DIMM group #1 has been disabled

0B61

DIMM group #2 has been disabled

0B62

DIMM group #3 has been disabled

Contact your service representative.

0B70

The error occurred during temperature
sensor reading.

Contact your service representative.

0B71

System Temperature out of the range.

Contact your service representative to replace
the fan.

0B74

The error occurred during voltage sensor
reading.

0B75

System voltage out of the range.

Contact your service representative.

0B80

BMC Memory Test Failed.

0B81

BMC Firmware Code Area CRC check failed.

0B82

BMC core Hardware failure.

0B83

BMC 1BF or 0BF check failed.

Turn off the power once and then on again to
start the server. If the error cannot be
corrected, contact your service representative.

0B8B

BMC progress check timeout.

0B8C

BMC command access failed.

0B8D

Could not redirect the console - BMC Busy -

0B8E

Could not redirect the console - BMC Error -

Turn off the power once and then on again to
start the server. If the error cannot be