beautypg.com

System management submenu – NEC Express5800/120Rh-2 N8100-1126F User Manual

Page 113

background image

Configuring Your Server 4-17

System Management Submenu

Option

Parameter

Description

Your Setting

BIOS Version

Displays the current BIOS version.
(View only)

IPMI Specification
Version

Displays IPMI specification version.
(View only)

BMC Device ID

Displays BMC device ID. (View only)

BMC Device
Version

Displays BMC device version. (View
only)

BMC Firmware
Version

Displays BMC firmware version. (View
only)

PIA Version

Displays version of the platform
information area. (View only)

SDR Revision

Displays revision of the sensor data
record.

[ ]: Factory-set

Console Redirection Submenu

Option

Parameter

Description

Your Setting

BIOS Redirection
Port

[Disabled]
Serial Port A
Serial Port B

Specify the address/interrupt of the
serial port to which a remote console
is connected.

ACPI Redirection
Port

[Disabled]
Serial Port A
Serial Port B

Specify the serial port to which an
ACPI console is connected.

Baud Rate

9600
[19.2K]
38.4K
57.6K
115.2K

Specify the baud rate used for the
interface with successive remote
consoles.

Flow Control

None
Xon/Xoff
[CTS/RTS]
CTS/RTS+CD

Specify the flow control method.

Console Type

[PC ANSI]
VT100+
VT-UTF8

Specify the type of remote console.

[ ]: Factory-set

Console Redirection Submenu

Option

Parameter

Description

Your Setting

Clear all Event
Logs

Press Enter and select "Yes" to clear
the system event log.