beautypg.com

Important – NEC Express5800/120Rh-2 N8100-1126F User Manual

Page 112

background image

4-16 Configuring Your Server

Option

Parameter

Description

Your Setting

Post Error Pause

Disabled
[Enabled]

Specify whether to stop the POST once
at the end of POST if an error occurs
during the POST.

AC-LINK

Stay Off
[Last State]
Power On

Specify the state of power when the AC
power to the server is turn off once and
then on.

Power On Delay
Time (Sec)

[0] - 255

Specify the power on delay time within
the range between 0 and 255 seconds.
The time specified is valid when "Power
On" or "Last State" is specified for AC
LINK.

Platform Event
Filtering

[Disabled]
Enabled

This item becomes meaningless when
the notification feature of remote
management card (RMC) is enabled.

[ ]: Factory-set

IMPORTANT:

To power on the server from the UPS (Uninterruptible

Power Supply), select [Server] - [AC LINK] - [Power On].

The table below shows the operation when the AC power to the server is turn off once and then on
again, depending on the setting of "AC LINK."

Setting of AC LINK

System status before AC power off

Stay Off

Last State

Power On

Operating

Off

On

On

Aborting (DC power being off also)

Off

Off

On

Forced shutdown

Off

Off

On

* Press the power switch continuously for four seconds or longer. This forcibly turns off the

power.