Chapter 4

Register Map and Descriptions

AT-MIO-16X User Manual

4-2

© National Instruments Corporation

Analog Output Register Group

DAC0 Register
DAC1 Register

10
12

Write-only
Write-only

16-bit
16-bit

ADC Event Strobe Register Group

CONFIGMEMCLR Register
CONFIGMEMLD Register
DAQ Clear Register
DAQ Start Register
Single Conversion Register
ADC Calibration Register

1B
1B

19

1D
1D

1F

Read-only
Write-only
Read-only
Read-only
Write-only
Write-only

8-bit
8-bit
8-bit
8-bit
8-bit
8-bit

DAC Event Strobe Register Group

TMRREQ Clear Register
DAC Update Register
DAC Clear Register

1F
18

1E

Read-only
Write-only
Read-only

8-bit
16-bit
8-bit

General Event Strobe Register Group

DMA Channel Clear Register
DMATCA Clear Register
DMATCB Clear Register
External Strobe Register
Calibration DAC 0 Load Register
Calibration DAC 1 Load Register

0B

19
09

1E

0A
1A

Read-only
Write-only
Read-only
Write-only
Write-only
Write-only

8-bit
8-bit
8-bit
8-bit
8-bit
8-bit

Am9513A Counter/Timer Register Group

Am9513A Data Register
Am9513A Command Register
Am9513A Status Register

14
16
16

Read-and-write
Write-only
Read-only

16-bit
16-bit
16-bit

Digital I/O Register Group

Digital Input Register
Digital Output Register

1C
1C

Read-only
Write-only

16-bit
16-bit

RTSI Switch Register Group

RTSI Switch Shift Register
RTSI Switch Strobe Register

0C
0E

Write-only
Write-only

8-bit
8-bit

Table 4-1. AT-MIO-16X Register Map (Continued)

Register Name

Offset

Address (Hex)

Type