DAQ Start Register

Accessing the DAQ Start Register location initiates a multiple A/D
conversion data acquisition operation.

Note:

Several other pieces of AT-MIO-16X circuitry must be set up before a data
acquisition run can occur. See Chapter 5, Programming.

Address:

Base address + 1D (hex)

Type:

Read-only

Word Size:

8-bit

Bit Map:

Not applicable, no bits used

Strobe Effect:

Initiates a programmed data acquisition sequence

Note:

Multiple A/D conversion data acquisition operations can be initiated in one
of three ways—by accessing the Start DAQ Register, or by detecting an
active-low signal on either the EXTTRIG* or the RTSITRIG* signal. To
trigger the board with the Start DAQ Register, the RTSITRIG signal in
Command Register 1 must be cleared. In addition, either the EXTTRIG*
signal should be unasserted, or the EXTTRIG_DIS signal in Command
Register 4 must be set. Otherwise, strobing the Start DAQ Register has no
effect.