beautypg.com

Digital i/o, Timing i/o – National Instruments AT-MIO-16X User Manual

Page 231

background image

Appendix A

Specifications

AT-MIO-16X User Manual

A-8

© National Instruments Corporation

Differential nonlinearity in a DAC is a measure of deviation of code
width from 1 LSB. For a DAC, code width is the difference between the
analog values produced by consecutive digital codes. A specification of
±0.5 LSB differential nonlinearity ensure that the code width is always
greater than 0.5 LSB (guaranteeing monotonicity) and less than 1.5
LSB.

Digital I/O

Compatibility ..................................... TTL-compatible

Output current source capability......... Can source 2.6 mA at V

OH

at

2.4 V min

Output current sink capability ............ Can sink 24 mA at V

OL

at

0.5 V max

Timing I/O

Number of channels ........................... 3 counter/timers

1 frequency output

Resolution .......................................... 16-bit for 3 counter/timers,

4-bit for frequency output
channel

Base clock available ........................... 5 MHz, 1 MHz, 100 kHz,

10 kHz, 1 kHz, 100 Hz

Base clock accuracy ........................... ±0.01%

Compatibility ..................................... TTL-compatible inputs and

outputs. Counter gate and source
inputs are pulled up with 4.7-k

resistors onboard.

Counter input frequency ..................... 6.9 MHz maximum (145-nsec

period) with a minimum pulse
width of 70 nsec