Digital i/o signal connections, Digital i/o signal connections -31 – National Instruments AT-MIO-16X User Manual
Page 53
Chapter 2
Configuration and Installation
© National Instruments Corporation
2-31
AT-MIO-16X User Manual
Digital I/O Signal Connections
The digital lines ADIO<0..3> are connected to digital I/O port A. The
digital lines BDIO<0..3> are connected to digital I/O port B. DIG GND
is the digital ground pin for both digital I/O ports. Ports A and B can be
programmed individually to be inputs or outputs.
The following specifications and ratings apply to the digital I/O lines.
Absolute maximum voltage input rating
5.5 V with respect to
DIG GND
Digital input specifications (referenced to DIG GND):
V
IH
input logic high voltage
2 V minimum
V
IL
input logic low voltage
0.8 V maximum
I
IH
input current load,
logic high input voltage
40
µ
A maximum
I
IL
input current load,
logic low input voltage
–120
µ
A maximum
Digital output specifications (referenced to DIG GND):
V
OH
output logic high voltage
2.4 V minimum
V
OL
output logic low voltage
0.5 V maximum
I
OH
output source current,
logic high
2.6 mA maximum
I
OL
output sink current, logic low
24 mA maximum
With these specifications, each digital output line can drive 11 standard
TTL loads and over 50 LS TTL loads.
Figure 2-12 depicts signal connections for three typical digital I/O
applications.