RTSI Switch Shift Register
The RTSI Switch Shift Register is written to in order to load the RTSI
switch internal 56-bit Control Register with routing information for
switching signals to and from the RTSI bus trigger lines. The RTSI
Switch Shift Register is a 1-bit register and must be written to 56 times
to shift the 56 bits into the internal register.
Address:
Base address + 0C (hex)
Type:
Write-only
Word Size:
8-bit
Bit Map:
Bit
Name
Description
7-1
0
Reserved
0
RSI
RTSI Switch Serial Input—This bit is the
serial input to the RTSI switch. Each
time the RTSI Switch Shift Register is
written to, the value of this bit is shifted
into the RTSI switch. See the
Programming the RTSI Switch section in
Chapter 5, Programming, for more
information.
7
6
5
0
4
3
0
2
0
1
0
0
0
0
RSI
0
LSB