Timing

The 316x DSU/CSU provides the ability to select a

master clock (timing) source that is used to synchronize
all of the T1 and data port interfaces on the DSU/CSU.
When a master clock source is selected, the DSU/CSU
will synchronize to the master clock and derive clocking
for all of the interfaces on the DSU/CSU. The clock for
each interface will be at the appropriate rate for that
interface (e.g., 1.544 Mbps for the T1 interfaces, the
configured port rate for the data ports) and independent of
the master clock rate. This means that the master clock
rate and the DSU/CSU interface rates may be different.
The DSU/CSU will automatically fall back to the internal
master clock when a failure of the selected master clock is
detected.

NOTE

For Model 3161 DSU/CSUs, the
external clock provides timing for
up to eight slots in the carrier.
Each Auxiliary Backplane must
have its own external clock input.

The DSU/CSU clock source configuration option

enables you to select one of five sources for the master
clock, either the Network T1 interface, the DSX-1
Drop/Insert T1 interface, Port 1, internal clock, or external
clock. If external clocking is selected, you must use the
clock rate configuration option to specify the clock rate.
Two examples for configuring timing are given below. For
more information on the configuration options, refer to
Appendix C. Figure 3-32 shows some common clocking
configurations.

496-14341a-01

3160/3164

NETWORK

CLOCK: NETWORK

3160/3164

CLOCK: NETWORK

3160/3164

CLOCK: NETWORK

CLOCK: INTERNAL

3160/3164

3160/3164

CLOCK: EXTERNAL

3160/3164

CLOCK: NETWORK

PBX

CLOCK: DTE (DSX-1 CONNECTOR)

3160/3164

CLOCK: NETWORK

3160/3164

TERMINAL

EQUIPMENT

CLOCK: PORT 1

3160/3164

CLOCK: NETWORK

3160/3164

Figure 3-32. Common Clocking Configurations