Configuration Options

C-13

3160-A2-GB22-10

December 1996

User Interface Configuration
Options

Table C-7

(1 of 4)

User Interface Configuration Options

Self-Test: Enab
Next Enab Disab Prev

Initial Self-Test. Specifies whether the DSU/CSU performs a device self-test at power-up and after a device reset.

Enab – Enables a self-test.

Disab – Disables the self-test.

FP Access: Enab
Next Enab Disab Prev

Front Panel Access. Determines whether front panel access or display is allowed at the DSU/CSU.

Enab – Allows the front panel to access and display data. This is the factory default.

Disab – Prevents the access and display of data.

FP Pass: Disab
Next Enab Disab Prev

Front Panel Pass-Through. Determines whether front panel pass-through is allowed at the DSU/CSU. Front panel
pass-through enables you to use the front panel (or PC attached to the COM port) to access the integral modem to dial to
a far-end 3160/3164 DSU/CSU. You can then use the local front panel as a remote dial-in front panel for the far-end
DSU/CSU.

Enab – Allows the front panel to perform a dial-out to the remote DSU/CSU front panel (enables pass-through). The Pass
command under the Call Setup branch (under Control) becomes available.

Disab – Prevents dial-out access to the remote DSU/CSU.

NOTE: This configuration option is not displayed on Model 3161 DSU/CSUs.

Dial-In: Disab
Next Enab Disab Prev

Dial-in Access. Controls access to the DSU/CSU through the dial-in (MODEM) port.

Enab – Allows dial-in access to the DSU/CSU. The integral modem will answer incoming calls, allowing a far-end
DSU/CSU front panel to access the near-end DSU/CSU menu tree or establish a connection for async terminal interface
or SNMP management access.

Disab – Prevents dial-in access. Incoming calls to the DSU/CSU will not be answered.

NOTE: This configuration option is not displayed on Model 3161 DSU/CSUs.

Password: None
Next None Modem Com Both Prev

Password Mode. Activates a password prompt that asks you to enter an 8-character (maximum) password at the calling
DSU/CSU or PC.

None – Does not specify a password. This is the factory default.

Modem – Prompts the remote modem port user to enter an alphanumeric, up to 8-character password.

Com – Prompts the communications port user to enter an alphanumeric, up to 8-character password.

Both – Prompts both the communications port user and the remote modem port user to enter an alphanumeric, up to