Technical Specifications

B-3

3160-A2-GB22-10

December 1996

Table B-2

(1 of 2)

ACCULINK Model 3161 DSU/CSU Technical Specifications

Specifications

Criteria

POWER REQUIREMENTS
Sixteen 3161 DSU/CSUs, plus SDU,
SDCP and fan module

115 Vac Power Supply
– 48 Vdc Power Unit

90 to 132 Vac, 60 Hz

±

3 (2.4 amp, 215 watts)

–38 to –60 Vdc (2.5 amps maximum)

POWER CONSUMPTION AND
DISSIPATION

9.3 watts per circuit card

DTE (DSX-1) INTERFACE
Physical Interface
Framing Format
Coding Format
DTE Line Equalization
Send AIS

DB15S
D4, ESF
AMI, B8ZS
5 selectable ranges from 0 to 655 feet (0 to 196.5 meters)
Selectable

NETWORK T1 INTERFACE
Physical Interface (USA)
Physical Interface (Canada)
Framing Format
Coding Format
Line Build-Out (LBO)
ANSI PRM
Bit Stuffing
Yellow Alarm Generation

RJ48H
CA81A (T1 using adapter cable)
D4, ESF
AMI, B8ZS
0.0 dB, –7.5 dB, –15 dB, –22.5 dB
Selectable
FCC Part 68, AT&T TR 62411
Selectable

LOOPBACKS
Standard
Additional

AT&T TR 54016, AT&T TR 62411, ANSI T1.403.1989
RLB (Repeater Loopback), DLB (DTE Loopback), V.54 Loop 2 and Loop 3,
ANSI T1.403 Annex B Fractional T1 Loopback

PORT INTERFACE
Standards
Rates

EIA 530A, V.35, RS–449, V.11
Nx64 – 64–1.536 Mb
Nx56 – 56–1.344 Mb

CLOCKING SOURCES

T1 network interface, DSX-1 T1 interface, Port 1, internal clock, external clock

APPROVALS
FCC Part 15
FCC Part 68
UL
CSA

Safety
Emissions
EMI

DOC

CS-03

ANSI

Class A digital device
Registration number AW2USA-20327-DD-N
Recognized component with 3000 Series Carrier, UL 1950

Certified component with 3000 Series Carrier, CSA 22.2 No. 950-M89,
Class A digital apparatus
Class A, CSA 108.8-M1983

Pending
ANSI T1.403-1989

PHYSICAL DIMENSIONS
Height
Width
Depth

7.1 inches (18.0 cm)
1.0 inches (2.5 cm)
14.2 inches (36.1 cm)