Deactivating the Alarm Relay

The Alarm Cut-off command forces a deactivation of

the alarm relay on the 3000 Series Carrier during an alarm
condition. Since this function only affects the 3000 Series
Carrier, it is only available for Model 3161 DSU/CSUs.
The alarm relay function must first be enabled by the
Alarm Relay configuration option (see Appendix C,
Configuration Options).

To deactivate the alarm relay,

1. Press the

key from the top-level menu screen

to bring the Ctrl branch onto the front panel LCD.

F1

DSU ESF
Stat

Test

Cnfig

F2

F3

2. Press F3 to select Ctrl from the top-level menu

screen.

F1

DSU ESF
Test

Cnfig

Ctrl

F2

F3

3. From the Control screen, press F1 to select ACO.

F1

Control:
ACO

Rel

LED

F2

F3

4. The Command Complete screen appears.

F1

Alarm Cut-Off:
Command Complete

F2

F3

Starting Front Panel
Emulation

The front panel emulation function enables you to

display the front panel of a specified near-end or far-end
316x DSU/CSU on a PC. If the DSU/CSU selected is not
locally attached to the PC, you must first dial to the
remote DSU/CSU before starting front panel emulation.

To start front panel emulation,

1. From the PC, open Program Manager from

Windows.

2. The Front Panel window opens.

NOTE

The modem attached to the PC
must support AT commands for
the Front Panel Emulation
software to successfully place the
call.