beautypg.com

Paradyne ACCULINK 316x User Manual

Page 157

background image

ACCULINK 316x DSU/CSU

C-16

December 1996

3160-A2-GB22-10

Table C-7

(4 of 4)

User Interface Configuration Options

Modem Type: Async
Next Async Sync Prev

Modem Type. Specifies whether the port uses synchronous or asynchronous communication when the modem port is
configured as the SNMP management link.

NOTE: This configuration option is not available if the Modem Use configuration option is set to ASCII or Term. In this

case, the modem port is always asynchronous.

Modem Rate: 2.4
Next 1.2 2.4 Prev

Modem Port Rate. Configures the bit rate for the MODEM port.

1.2 – Sets the bit rate at 1200 bps.

2.4 – Sets the bit rate at 2400 bps.

NOTE: This configuration option is not displayed on Model 3161 DSU/CSUs.

MChar Len: 8
Next 7 8 Prev

Modem Character Length. Configures the character length (number of data bits) for the modem port. This does not
include the start bit (always 1) or the stop bits; 8 is the factory default.

NOTE: This configuration option must be set to 8 to perform PC emulation or pass-through operations, or SNMP

management.

NOTE: This configuration option is not displayed on Model 3161 DSU/CSUs.

MParity: None
Next None Even Odd Prev

Modem Parity. Configures the parity for the MODEM port. None is the factory default.

NOTE: This configuration option is not displayed on Model 3161 DSU/CSUs.

MStop Bits: 1
Next 1 2 Pre

Modem Port Stop Bits. Configures the number of stop bits for the MODEM port; 1 is the factory default.

NOTE: This configuration option is not displayed on Model 3161 DSU/CSUs.

LSpacDsc: Disab
Next Enab Disab Pre

Long Space Disconnect. Specifies how the modem disconnects a call. This configuration option makes call disconnecting
more robust and prevents invalid data at the remote modem when the call is disconnected. To be effective, the remote
modem must be configured to disconnect when it detects continuous space.

NOTE: This configuration option is not displayed on Model 3161 DSU/CSUs.