Selecting the number of trap managers – Paradyne ACCULINK 316x User Manual
Page 74
ACCULINK 316x DSU/CSU
3-32
December 1996
3160-A2-GB22-10
Selecting the Number of Trap Managers
If you intend to issue traps to an SNMP manager(s)
from this device, you must specify the number of SNMP
managers that are to receive the traps.
To specify the number of SNMP managers to receive
traps from this device,
1. Press F3 to select Cnfig from the top-level menu
screen.
F1
DSU ESF
Stat
Test
Cnfig
F2
F3
2. Select the configuration option set to be copied
into the Edit area by using the appropriate
function key. Use the scroll keys, if necessary.
F1
Load from:
Activ
Cust
Fact1
F2
F3
3. Press F1 to select Edit.
F1
Choose Funct:
Edit
Save
F2
F3
4. Press the
key from the Edit screen to display
the SNMP selection.
F1
Edit:
DTE
Port
NET
F2
F3
5. Press F3 to select SNMP.
F1
Edit:
User
Alarm
SNMP
F2
F3
6. Press F2 to select Trap from the SNMP Config
screen.
F1
SNMP Config:
Gen
Trap
F2
F3
7. Select the number of SNMP managers to receive
traps (from 1 through 6) by using the appropriate
function key. Use the scroll keys, if necessary.
F1
Num Trap Mgrs:1
Next
1
2
F2
F3
Differences Using the Async Terminal: To set the
number of trap managers, select Trap Options from the
main/configuration/edit/snmp menu. Figure 3-23 shows
an example of the screen that appears.