beautypg.com

48 vdc single source power supply pinouts, Installing the single – 48 vdc power supply – Paradyne ACCULINK 316x User Manual

Page 30

background image

Installation

2-7

3160-A2-GB22-10

December 1996

Installing the Single –

ā

48 Vdc Power Supply

To install the 3160/3164 DSU/CSU using a single

source – 48 Vdc power supply, refer to Figure 2-8 and use
the following procedure.

To install the – 48 Vdc single source power supply,

1. Connect the black and red wires to the – 48 Vdc

return source.

2. Connect the green wire to a suitable earth ground.

3. Connect the orange and blue wires to the –

ā48 Vdc

input source.

4. Cut the white wire off at the outer insulation.

5. Plug the power connector into the 3160/3164

DSU/CSU.

Figure 2-8. –

ā

48 Vdc Single Source Power Supply Pinouts