Table 4-3
Valid Send Test Pattern Combinations
QRSS (Network)
QRSS (Port)
1 in 8 (Network)
511 (Port)
QRSS (Network)
N/A
NO
NO
NO
QRSS (Port)
NO
YES (on
separate ports)
N/A
YES (on
separate ports)
1 in 8 (Network)
NO
NO
N/A
NO
511 (Port)
NO
N/A
N/A
YES (on
separate ports)
Monitoring Test Patterns
Use the Monitor command to monitor a QRSS test
pattern over all the channels on the network interface, or
to monitor QRSS or 511 test patterns on the channels
allocated to an individual port.
This command provides the number of errors detected
in the test pattern (5 digits, maximum 99999).
To monitor a QRSS or 511 test pattern,
1. Press F2 to select Test from the top-level menu
screen.
F1
DSU ESF
Stat
Test
Cnfig
F2
F3
2. From the Test screen, press F3 to select Ptrns.
F1
Test:
Rlpbk Lpbk
Ptrns
F2
F3
3. From the Patterns screen, press F3 to select Mon.
F1
Patterns:
Abort
Send
Mon
F2
F3
4. From the Patterns Mon screen, press F1 for QRSS
or F2 for 511.
F1
Patterns: Mon
QRSS 511
F2
F3
5. From the Monitor screen, press the function key
that corresponds to the network or port for which
you want to monitor a test pattern. Use the scroll
keys, if necessary. (NET does not appear for the
511 pattern.)
F1
Monitor:
Name
NET
Prt1
Prt2
F2
F3
The Monitor screen appears with the error count.
If the maximum of 99999 is exceeded, OvrFlw
appears instead of the count. If the receiver loses
synchronization while the monitor is active,