Table 4-3

Valid Send Test Pattern Combinations

QRSS (Network)

QRSS (Port)

1 in 8 (Network)

511 (Port)

QRSS (Network)

N/A

NO

NO

NO

QRSS (Port)

NO

YES (on

separate ports)

N/A

YES (on

separate ports)

1 in 8 (Network)

NO

NO

N/A

NO

511 (Port)

NO

N/A

N/A

YES (on

separate ports)

Monitoring Test Patterns

Use the Monitor command to monitor a QRSS test

pattern over all the channels on the network interface, or
to monitor QRSS or 511 test patterns on the channels
allocated to an individual port.

This command provides the number of errors detected

in the test pattern (5 digits, maximum 99999).

To monitor a QRSS or 511 test pattern,

1. Press F2 to select Test from the top-level menu

screen.

F1

DSU ESF
Stat

Test

Cnfig

F2

F3

2. From the Test screen, press F3 to select Ptrns.

F1

Test:
Rlpbk Lpbk

Ptrns

F2

F3

3. From the Patterns screen, press F3 to select Mon.

F1

Patterns:
Abort

Send

Mon

F2

F3

4. From the Patterns Mon screen, press F1 for QRSS

or F2 for 511.

F1

Patterns: Mon
QRSS 511

F2

F3

5. From the Monitor screen, press the function key

that corresponds to the network or port for which
you want to monitor a test pattern. Use the scroll
keys, if necessary. (NET does not appear for the
511 pattern.)

F1

Monitor:

Name

NET

Prt1

Prt2

F2

F3

The Monitor screen appears with the error count.
If the maximum of 99999 is exceeded, OvrFlw
appears instead of the count. If the receiver loses
synchronization while the monitor is active,