Paradyne ACCULINK 316x User Manual

Page 72

background image

ACCULINK 316x DSU/CSU

3-30

December 1996

3160-A2-GB22-10

2. Select the configuration option set to be copied

into the Edit area by using the appropriate
function key. Use the scroll keys, if necessary.

F1

Load from:
Activ

Cust

Fact1

F2

F3

3. Press F1 to select Edit.

F1

Choose Funct:
Edit

Save

F2

F3

4. Press the

key from the Edit screen to display

the SNMP selection.

F1

Edit:
DTE

Port

NET

F2

F3

5. Press F3 to select SNMP.

F1

Edit:
User

Alarm

SNMP

F2

F3

6. Press F1 to select Gen from the SNMP Config

screen.

F1

SNMP Config:
Gen

Trap

F2

F3

7. Press the F1 (Next) key until the

CommunityName1 configuration option appears.

F1

System Name:
Next

Edit

Clear

F2

F3

8. Press F2 (Edit) to edit the community name. The

factory default community name is public.

F1

CommunityName1:
Next

Edit

Clear

F2

F3

NOTE

Steps 9 and 10 describe the
process for entering text strings
for SNMP configuration options.
This process applies to entering
any text strings into SNMP
configuration options.

9. Use the

and

keys to position the cursor

under the character you want to change. Press F1
(Up) or F2 (Down) to scroll through the valid
numbers/characters for the text string. The valid
characters consist of the set of printable ASCII
characters. The F1 (Up) key scrolls through the
ASCII character set in the following order:
numbers (0–9), lowercase letters (a–z), uppercase
letters (A–Z), space character, ASCII symbols
(ascending order, based on ASCII code), and the
End of Line symbol (

). The

erases all

characters to the right of the cursor.

F1

public
Up

Down

Save

F2

F3