Remote loopback tests, Sending a line loopback up or down – Paradyne ACCULINK 316x User Manual

Page 120

background image

ACCULINK 316x DSU/CSU

4-4

December 1996

3160-A2-GB22-10

When you select T1 Interface Loopbacks and

Patterns, the subsequent screen displays the Remote
Loopback, Local Loopback, Send, Monitor, and Abort
operations that are available to run on the T1 interface, as
shown in Figure 4-2. Likewise, from one of the port
selections, a similar screen appears with the same
operations that can run on the selected port, also shown in
Figure 4-2. All the local loopback tests are mutually
exclusive with the send pattern and remote loopback tests.
If you attempt to run a test that is already active or an
invalid local loopback test or test pattern combination (see
Tables 4-2 and 4-3), an error message is displayed.

The Lamp test is not available from the async terminal

interface.

Remote Loopback Tests

The Remote Loopback tests allow you to troubleshoot

your circuit by sending to a far-end DSU/CSU the
following:

For Networks,

Line loopback up code for 10 seconds (LLBUP)

Line loopback down code for 10 seconds (LLBDN)

For Channels,

V.54 activation sequence to initiate a V.54 Loop 2
(54UP)

V.54 deactivation sequence to terminate a
V.54 Loop (54DN)

ANSI T1.403 (Annex B) activation sequence to
initiate a DCLB on the remote device (FT1UP)

ANSI T1.403 (Annex B) deactivation sequence to
terminate a DCLB on the remote device (FT1DN)

You cannot perform remote loopbacks if any of the

local loopbacks are active. If you attempt to do so, the
error message Invalid Test Combo appears.

Sending a Line Loopback Up or Down

To send a Line Loopback Up or Down code on the

network to a far-end DSU/CSU,

1. Press F2 to select Test from the top-level menu

screen.

F1

DSU ESF
Stat

Test

Cnfig

F2

F3

2. From the Test screen, press F1 to select Rlpbk.

F1

Test:
Rlpbk Lpbk

Ptrns

F2

F3

3. From the Rem Loopback screen, press F1 to select

LLBUP (Line Loopback Up), or press F2 to select
LLBDN (Line Loopback Down).

F1

Rem Loopback:
LLBUP LLBDN 54UP

F2

F3

The Local Loopback code is sent up or
downstream to the far-end DSU/CSU for
10 seconds. During this time, Sending appears on
Line 2 of the LCD, followed by Command
Complete
when 10 seconds have elapsed.

You can press any function key to restore the Rem
Loopback screen without affecting transmission of
the loopback code.