Optional power selection, 24 vdc power supply pinouts, Installing the +24 vdc power supply – Paradyne ACCULINK 316x User Manual

Page 29

background image

ACCULINK 316x DSU/CSU

2-6

December 1996

3160-A2-GB22-10

5. If you intend to manage the 3160/3164 DSU/CSU

with SNMP, cable either the COM or MODEM
port (as appropriate for your configuration). Then,
configure the SNMP management link. See
Chapter 3, Operation, and Appendix C,
Configuration Options, for more information.

6. If you do not intend to use the DTE Drop/Insert

T1 port, disable it using the configuration
procedures in Chapter 3, Operation, and
Appendix C, Configuration Options. (The default
setting for this port is Enabled.)

7. The Factory 1 configuration for ESF framing

format and B8ZS line coding format is the default
configuration and is appropriate for most
networks. If this configuration does not work for
you, try the Factory 2 configuration for D4
framing format and AMI line coding format. To
further customize configuration options, refer to
the Configuring the DSU/CSU section in
Chapter 3, Operation, and to Appendix C,
Configuration Options.

8. Verify that the DSU/CSU is functional by

observing that the OK and NETWORK SIG
LEDs are lit.

9. Configure the ports and channels you intend to use

and assign channels to the network interface. To
do so, refer to Configuring the DSU/CSU section

in Chapter 3, Operation, and to Appendix C,
Configuration Options.

Optional Power Selection

Using the optional dc power cable, the 3160/3164

DSU/CSU is capable of operating on either a +24 Vdc
power source, –48 Vdc single source battery, or – 48 Vdc
redundant source batteries (for power backup). To select
the power, choose one of the following power supply
types.

Installing the +24 Vdc Power Supply

To install the 3160/3164 DSU/CSU using a +24 Vdc

power supply, refer to Figure 2-7 and use the following
procedure.

To install the +24 Vdc power supply,

1. Connect the green wire to a suitable earth ground.

2. Connect the white wire to the +24 Vdc return.

3. Connect the orange wire to the +24 Vdc source.

4. Cut the black, red and blue wires off at the outer

insulation.

5. Plug the power connector into the 3160/3164

DSU/CSU.

Figure 2-7. +24 Vdc Power Supply Pinouts