beautypg.com

Data port leds – Paradyne ACCULINK 316x User Manual

Page 52

background image

ACCULINK 316x DSU/CSU

3-10

December 1996

3160-A2-GB22-10

Table 3-4

Data Port LEDs

Name

Color

Meaning

DTR

Green

Monitors the state of interchange circuit CD (CCITT 108/1, /2) – DTE Ready received
from the DTE.

ON :

DTR is being asserted by the DTE.

OFF :

DTR is not being asserted.

TXD

Yellow

Monitors activity on interchange circuit BA (CCITT 103) – Transmitted Data. This is the
data sent from the DTE to the DCE on the DSU/CSU.

ON :

Ones are being received from the DTE.

OFF :

Zeros are being received from the DTE.

CYCLING: Both ones and zeros are being received from the DTE.

RXD

Yellow

Monitors activity on interchange circuit BB (CCITT 104) – Received Data. This is data
sent to the DTE from the DCE on the DSU/CSU.

ON :

Ones are being sent to the DTE.

OFF :

Zeros are being sent to the DTE.

CYCLING: Both ones and zeros are being received from the DTE.

CTS

Yellow

Monitors the state of interchange circuit CB (CCITT 106) – Clear to Send sent to the
DTE.

ON :

CTS is being asserted by the DSU/CSU.

OFF :

CTS is not being asserted.

RTS

Yellow

Monitors the state of interchange circuit CA (CCITT 105) – Request to Send received
from the DTE.

ON :

RTS is being asserted by the DTE.

OFF :

RTS is not being asserted.