ACCULINK 316x DSU/CSU

C-2

December 1996

3160-A2-GB22-10

Context-Sensitive Menu

This DSU/CSU is an intelligent device that displays

only those options that are valid for the current
configuration. Therefore, you will only be presented with
menu choices that are consistent with the current
configuration and operational state of the DSU/CSU;
invalid combinations of configuration options are not
displayed. Although all options are shown in this manual,
what you see on your DSU/CSU varies with your
configuration.

DTE Interface Configuration
Options

Table C-1

(1 of 2)

DTE Interface Configuration Options

DTE Port: Enab
Next Enab Disab Prev

DTE Drop/Insert T1 Port. Enables the use of the DTE Drop/Insert port.

Enab – Allows the use of the DSX-1 Drop/Insert T1 interface.

Disab – Prohibits the use of the DSX-1 Drop/Insert T1 interface.

NOTE: When this configuration option is disabled, you cannot display or configure any other DTE Interface configuration

options.

DTE Framing: ESF (Factory 1) D4 (Factory 2)
Next D4 ESF Prev

DTE Line Framing Format. Designates the framing format for the DTE T1 interface.

D4 – Configures for the D4 framing format.

ESF – Configures for the Extended Superframe framing format.

DTE Coding: B8ZS (Factory 1) AMI (Factory 2)
Next AMI B8ZS Prev

DTE Line Coding. Designates the line coding format to be used on the DTE interface.

AMI – Uses the Alternate Mark Inversion coding format.

B8ZS – Uses the Bipolar 8 Zero Suppression coding format.

Equal: 0—133
Next 0—133 133—266 266—399 399—533 533—655 Prev

DTE Line Equalization. Specifies the DTE line equalization compensation parameters which permit a standard DSX
signal to be delivered over a distance of up to 655 feet.