Symbol Technologies AP-5131 User Manual
Page 534

AP-5131 Access Point Product Reference Guide
9-38
7.
The Trion IT department leaves the
Priority
setting to at 32768 for AP5 and AP6 for both to
defer to AP1 (which was assigned a priority of 1 for root designation) as the AP-5131
defining the mesh network configuration.
The remainder of the Mesh STP Configuration settings are left unchanged from their default
values. The team clicks
OK
from within the Mesh STP Configuration screen and
Apply
from
within the trion (LAN1) screen to save the settings.
The Trion IT team now intends to assign WLANs (to use with the trion LAN) that can be
dedicated to their mesh network within the shipping yard.
8.
The team selects
Network Configuration
->
Wireless
from the AP-5131 menu tree.
The
Wireless Configuration
screen displays with those existing WLANs displayed within
the table. Since this is Trion’s first deployment for AP5 and AP6, the IT department
determines the existing default WLAN should be left as is, and a new WLAN should be
configured resembling the mesh network WLAN defined for APs 1-4.