Symbol Technologies 1-PortPower-over-Ethernet User Manual
Power injector, Port power-over -ethernet, Installation guide
To t
he Instal
ler
This guide
is intended f
or th
e tech
nician responsib
le for
installing the Symbol Po
wer Injector.
It assumes the technician is
familiar with basic Eth
ernet LAN-ba
sed
networking
and
de
vice
installation concepts. This g
uid
e provides
specifications,
proce
dures and guidelines to use
during the inst
allation process. This gu
ide doe
s not provide site-spe
cific
installation
procedures. For detaile
d site-specific installa
tion p
rocedures, re
fer to the
site-specific
documentatio
n d
erived
from site
survey and site network analysis.
Verifying Package Conten
ts
Inspect th
e pa
ckage c
ontents and report any missin
g or
dama
ged items to your
sales
represe
ntativ
e. The packages should c
ontain
the
following:
• Po
wer Injector (pt # AP-PSBIAS-1P2-AFR)
•This Power Inje
ctor Installa
tion Guide (72-70762
-01)
Safety
Information
Before ope
rating an
y equipmen
t, revie
w this do
cument
for any haz
ards associate
d with
installation and use of the device. Also, re
view s
tandard practices
for
preve
ntin
g accidents.
•Only trained
and qu
alified personnel
shoul
d install and remove the Power In
jector.
•A powe
r cord is not supplied with the de
vice. Use only a correctly rated power cord th
at’ s
certified, as appropriate
, for the c
ountry
of
operation.
• The
power co
rd must be a
three-c
onductor
type (two current carrying
conductors
and one
ground conductor) termina
ted on
one end by
an IEC
60320 applian
ce
coupler (for
Power
Injector con
nection) and on the other
end
by a plug
conta
ining a ground
(earth)
contact.
• The po
wer cord
must be rated
for a minimu
m of 250V
AC RMS operation, with a
minimum
rated curr
ent capcity
of 5A
[or a minimu
m wire gauge
of 18A
WG (0.7
5mm²)].
• The AC wall-socket outlet must
be near the
Power
Inje
ctor
and
easily
accessible.
• The Power Injector Da
ta an
d Da
ta
& P
owe
r interfaces are qualified as SEL
V (Safety
Extra-L
ow
Volt
age) circuits according to
to IEC 609
50. These
interfaces can
only be
connected
to SELV
interfaces on
other e
quipm
ent.
Wa
rn
ings
• Rea
d th
e installation instruction
s befo
re con
necting th
e Power Injector
to a
powe
r source.
•Follow basic electricity
safety
measures wheneve
r conne
cting the Power Inje
cto
r to its
powe
r source.
•This product
relies on o
n th
e building
installation
for short-circuit
(over cu
rrent)
protection
. Ensure a fuse or circuit brea
ker
no larger than 120
VA
C, 3A U.S. (240V
AC,
1.5A international)
is used on the phase condu
cto
r.
•A volatg
e mismatch can cause
equipment dam
age a
nd could
pose a
fire haz
ard. If the
voltage indicat
ed on th
e label is
different
from the p
ower o
utle
t voltage,
do not con
nect
the Po
wer Injector to
that pa
rticular outlet.
•The Power Inje
ctor
Da
ta In
and Da
ta & Po
wer Ou
t po
rts are shielded
RJ-45
soc
kets.
Only RJ-4
5 data con
nectors should
be conne
cte
d to
these
sockets.
Service Inf
ormation
Before using
the
unit,
it must be
configure
d to
ope
rate in the facility’ s network and run y
our
applicatio
ns.
If you have a problem
runnin
g yo
ur
unit or using
your equipment, c
ontact
your
facility’ s T
echnical
or Syste
ms Su
pport. If t
here is a problem with
the equipment, th
ey will
contact the Symbo
l Su
pport Center:
For the latest
version of
this guid
e g
o to
: htt
p:/
/www.s
ymbol.com/manua
ls/
United St
ates
1-80
0-653-
5350
1-63
1-738-
2400
Canad
a
905-62
9-7226
United Kin
gdom
0800
328
2424
Asia
/Pac
ific
+65-67
96-960
0
Austr
alia
1-80
0-672-
906 Aus
tria
/Ös
ter
rei
ch
1-505-
5794-
0
Denmar
k/Dan
mark
7020-
1718
Fin
land/Suo
mi
9 54
07 580
Franc
e
01-
40-9
6-52-
21
German
y/Deu
tsc
hlan
d
6074-4
9020
Italy
/It
alia
2-48
4441
Mexic
o/Méx
ico
5-520-
1835
Neth
erlands
/Neder
land
315-
271700
Norw
ay/Nor
ge
+47 2232 437
5
South
Afri
ca
11-8
095311
Spain
/Es
paña
91 324
40 00
Inside Spain
Sweden
/Sv
erige
844529
00
+34 91 324 40
00
Outsi
de Spain
Lati
n Ame
ric
a
Sales
Support
1-80
0-347-
0178 In
side US
+1-9
54-255
-2610 O
uts
ide US
Europe
/Mid-Ea
st
Distr
ibu
tor O
perat
ions
Contac
t loc
al d
ist
ribut
or or
call
+44 11
8 945 73
60
Power Injector
1-Port Power-over
-Ethernet
Installation Guide
72-7076
2-01
Revision A January
2006
(2)
(1)
(3)
(4)
(5)
(6)
Introduction
When users purchase a Symbol WLAN solution, they often need to place access points in
obscure locations. In the past, a dedicated 24-hour, 90-264 VAC power source was required for
each access point in addition to the Ethernet infrastructure. This often required an electrical
contractor to install power drops at each access point location. With the Symbol Power Injector
solution (pt # AP-PSBIAS-1P2-AFR), centralized power can be provided for devices without a
local power supply for each.
Product Description
The Symbol Power Injector (pt # AP-PSBIAS-1P2-AFR) is a single-port, 802.3af compliant Power
over Ethernet hub combining low-voltage DC with Ethernet data in a single cable connecting
to an AP. The Power Injector’s single DC and Ethernet data cable creates a modified Ethernet
cabling environment eliminating the need for separate Ethernet and power cables.
The Power Injector is a small lightweight unit with a RJ-45 Ethernet cord input connector from
the hub on the front right-hand side of the unit and a RJ-45 data and power output connector
to the AP on the front left-hand side of the unit. On the back of the unit is a 110-220 VAC power
input.
A separate Power Injector is required for each device comprising the network.
The Symbol Power Injector supports the following Symbol device product families (all models
of the those listed):
•AP 100
•AP 200
•AP 300
•AP-5131
Caution - Using the Power Injector with an unsupported Symbol device could
render the device inoperable and void your warranty.
The Power Injector has the following features:
•Independent power controller (SPEAR™), CPU controller and input (Data) and output
(Data + Power) shielded RJ-45 connectors
•Supports standard 10/100BaseT Ethernet networks over a standard TIA/EIA-568
Category 5 (or higher) cabling
•Meets the IEEE 802.3af standard
•Universal AC Input: 110/220 V, 60/50 Hz.
•Minimum port output continuous allowable power of 15.4W at 48V
(minimum 12.95W at the PDTE)
•Underload, overload, short-circuit & under/over voltage port protection.
•Port Status and Main power LED indicators
•Standalone or wall mount installation support
• Interconnection option with other Power Injector units.
Technical Specifications
Physical Specifications
Width
58.5mm
Height
31mm
Depth
145mm
Weight
450gr
Environmental Specifications
Operating Temperature
0°C to 40°C (32°F to 104°F)
Storage Temperature
-20°C to 70°C (-4°F to 158°F)
Operating Humidity
10% to 93% Non-condensing
Storage Humidity
10% to 93% Non-condensing
Electrical Specifications
Input Voltage
90VAC to 264VAC (47Hz - 63Hz)
Maximum Output Power
.15.4 W
Nominal Output Voltage
48VDC
Ethernet Interface
Input (Data In)
Ethernet 10/100Base-T
(RJ-45 female socket)
Output (Data & Power Out)
Ethernet 10/100Base-T, plus 48VDC
RJ-45 female socket, with DC voltage
on pairs 7-8 and 4-5
Installation
Preparing for Site Installation
The Power Injector can be installed free standing, on an even horizontal surface or wall
mounted using the power injector’s wall mounting key holes.
The following guidelines should be adhered to before cabling the Power Injector to the Ethernet
source and Symbol device:
•Verify the device receiving converged power and Ethernet from the Power Injector is a
product approved by Symbol (AP100, AP200, AP300 and AP-5131).
•Do not block or cover airflow to the Power Injector.
•Keep the Power Injector away from excessive heat, humidity, vibration and dust.
•The Power Injector is not a repeater, and does not amplify the Ethernet data signal. For
optimal performance, ensure the Power Injector is placed as close as possible to the
network data port. Do not configure the cable length between the Ethernet network
source, the Power Injector and the Symbol AP beyond 100 meters (333ft).
Cabling the Power Injector
To install the Power Injector to an Ethernet data source and Symbol device:
Caution - Ensure AC power is supplied to the Power Injector using an AC cable
with an appropriate ground connection approved for the country of operation.
1. Connect the Power Injector to an AC outlet (110VAC to 220VAC).
2. Connect RJ-45 Ethernet cable between the network data supply (host) and the Power
Injector Data In connector.
3. Connect a RJ-45 Ethernet cable between the Power Injector Data & Power Out connector
and the Symbol device receiving converged power and Ethernet.
to AP-5131 LAN
Port
Data
Power
AP-5131
Power
Injector
Wireless LAN