Displaying current vlans, Displaying current vlans -66 – SMC Networks TigerSwitch 100 User Manual
Page 96

C
ONFIGURING
THE
S
WITCH
2-66
Displaying Current VLANs
The VLAN Current Table shows the current port members of each
VLAN and whether or not the port supports VLAN tagging. Ports
assigned to a large VLAN group that crosses several switches should use
VLAN tagging. However, if you just want to create a small port-based
VLAN for one or two switches, you can disable tagging.
Command Attributes for Web Interface
•
VLAN ID – ID of configured VLAN (1-4094, no leading zeroes).
•
Up Time at Creation – Time this VLAN was created; i.e., System Up
Time.
•
Status – Shows how this VLAN was added to the switch.
- Dynamic GVRP: Automatically learned via GVRP.
- Permanent: Added as a static entry.
•
Tagged Ports – Shows the tagged VLAN port members.
•
Untagged Ports – Shows the untagged VLAN port members
Console#show bridge-ext
Max support vlan numbers: 255
Max support vlan ID: 4094
Extended multicast filtering services: No
Static entry individual port: Yes
VLAN learning: IVL
Configurable PVID tagging: Yes
Local VLAN capable: No
Traffic classes: Enabled
Global GVRP status: Enabled
GMRP: Disabled
Console#