beautypg.com

Sun Microsystems Virtual Tape Library User Manual

Page 260

background image

246

VTL User Guide • May 2008

G • 96267

1074

Error

Replication cannot proceed -- unable to allocate memory.

1075

Error

Replication cannot proceed -- unexpected error %1.

1076

Informational

Starting replication for virtual device %1 of group %2 to replica device %3.

1077

Informational

Replication for group %1 has completed successfully.

1079

Error

Replication for group %1 has failed due to error on virtual device %2

1082

Error

Replication for virtual tape %1 has been manually aborted by user

1083

Error

Replication for group %1 has been manually aborted by user

1084

Error

A SCSI command terminated with a recovered error condition. This may indicate

that the device is becoming less reliable. Please check the system log for

additional information.

1085

Error

for virtual device %1 has been auto-disabled due to an error.

1086

Error

Replication cannot proceed -- failed to load the virtual tape %1.

1087

Error

Replication cannot proceed -- virtual tape %1 is in the drive.

1088

Error

Replication cannot proceed -- failed to set initialization status in

VirtualLibrary System for virtual tape %1.

1089

Informational

No data has been updated to the virtual tape %1 since last replication.

Replication is completed without updating the replica.

1201

Warning

Kernel memory is low. Add more memory to the system if all possible! Restart

the host if possible.

1202

Informational

Path trespassed to %1 successfully.

1203

Error

Path failed to trespass to %1.

1204

Error

Failed to add path group. ACSL: %1.

1205

Informational

Activated path successfully: %1.

1206

Error

Failed to activate path: %1.

1207

Error

Critical path failure detected. Path %1 will be removed.

1208

Warning

Path %1 does not belong to active path group.

1209

Informational

Rescan the FC adapters is recommended to correct the configuration.

1210

Warning

No valid path is available for device %1.

1211

Warning

No valid group is available.

1212

Warning

"No active path group found. Storage connectivity failure. Check cables,

switches and storage system to determine cause. GUID: %1."

1213

Informational

Storage device added new path: %1.

1214

Error

Failed to add path: %1.

2000

Informational

Path status has changed : %1

7000

Informational

Patch %1 installation completed successfully.

7001

Error

Patch %1 failed -- environment profile is missing in /etc.

Trap

Severity

Message