beautypg.com

Snmp traps – Sun Microsystems Virtual Tape Library User Manual

Page 257

background image

96267 • G

243

APPENDIX

D

SNMP traps

The VTL product family defines the following Simple Network Management 
Protocol (SNMP) traps. 

Trap

Severity

Message

9

Error

SCSI Port Error -- %1.

1000

Error

Socket connection could not be terminated properly -- %1.

1001

Error

Socket connection could not be terminated properly due to error during

shutdown -- %1.

1002

Error

Unexpected interrupt occurred.

1003

Informational

"VTL Server has detected virtual device[%1] at SCSI %2, channel %3, ID %4, LUN

%5."

1004

Informational

VTL Server has not detected any virtual device.

1005

Error

Out of kernel resources. Failed to get major number for VTL SCSI device.

1006

Error

Failed to allocate memory.

1007

Error

Failed to set up the network connection due to an error in SANRPC_Init -- %1.

1008

Error

Failed to set up the network connection due to an error in SANRPCListen -- %1.

1009

Informational

There are %1 real device(s) associated with virtual device [%2].

1010

Informational

Real Device[%1 %2 %3 %4].

1011

Error

Error while writing -- write(%1) result = 0x%2 cmd = 0x%3.

1012

Error

Error while reading -- read(%1) result = 0x%2 cmd = 0x%3.

1013

Informational

VTL Server [Build %1] is running on Linux %2.

1014

Informational

VTL Server has been shut down.

1015

Informational

"Maximum SCSI devices reached. On your VTL Server, verify with the command:

cat /proc/scsi/scsi"

1016

Informational

Primary virtual device %1 has failed. VTL is switching to the secondary

virtual device.

1017

Informational

Secondary virtual device %1 has failed.