Monitoring voltages, To monitor voltage, Viewing and managing the event log – Sun Microsystems Sun Fire X4150 User Manual
Page 40
24
Sun Fire X4150 Server Embedded Lights Out Manager Administration Guide • September 2007
A similar panel is repeated for each monitored entity.
Monitoring Voltages
▼
To Monitor Voltage
●
From the Sensor Reading tab, click the Voltage tab.
The Voltage screen appears. The Voltage screen displays the critical and
noncritical thresholds, the actual sensor reading, and the status for the nine
monitored DC system voltage lines. The Sensor Reading value represents the
actual voltage reading for that sensor.
shows a sample from the
Voltage screen. The sample is for the Vcc 12V line:
Viewing and Managing the Event Log
The Event Logs screen allows you to view and manage the system event log (SEL).
The SEL is a record of event occurrences. To record events in the SEL, you must have
previously determined which events require logging. See
“Configuring Platform
Event Filters” on page 27
.
TABLE 3-14
Sample of the Voltage Monitor Screen
Description
Vcc 12V
Lower noncritical threshold is readable:
11.999
Lower critical threshold is readable:
10.821
Upper noncritical threshold is readable:
12.837
Upper critical threshold is readable:
13.215
Sensor Reading:
12.081
Status:
ok