3. Display EventFilterTable1 by entering the following command:
/SP/AgentInfo/PEF/EventFilterTable1–> show
The result of executing the show command appears:
Next, set the sensor type. There are six values for the sensor type: All, Memory,
Processor, Temperature, Voltage, and Fan.
4. Use the set command to configure the sensor type.
set
sensortype=value
For example, to set the temperature sensor, enter:
/SP/AgentInfo/PEF/EventFilterTable1–> set sensortype=Temperature
5. Enable the properties or triggered actions for the sensor.
6. Use the set command to enable (or disable) actions. For example, to set the
sendalert and sendmail actions, enter:
/SP/AgentInfo/PEF/EventFilterTable1–> set sendalert=enable
/SP/AgentInfo/PEF/EventFilterTable1–> set sendmail=enable
/SP/AgentInfo/PEF/EventFilterTable1
Targets:
Properties:
Status = enable
SensorType = All
PowerCtrl = disable
DiagnosticInterrupt = disable
SendAlert = disable
SendMail = disable
Target Commands:
show