beautypg.com

Channel-group, Channel-group -178 – SMC Networks SMC EZ 10/100/1000 SMCGS8P-Smart User Manual

Page 346

background image

C

OMMAND

L

INE

I

NTERFACE

3-178

• All ports in a trunk must consist of the same media type (i.e.,

twisted-pair or fiber).

• All ports in a trunk must be configured in an identical manner,

including communication mode (i.e., speed, duplex mode and
flow control), VLAN assignments, and CoS settings.

• All the ports in a trunk have to be treated as a whole when

moved from/to, added or deleted from a VLAN via the specified
port-channel.

• STP, VLAN, and IGMP settings can only be made for the entire

trunk via the specified port-channel.

channel-group

Use this command to add a port to a trunk. Use the no form to
remove a port from a trunk.

Syntax

channel-group channel-id
no channel-group

channel-id - Trunk index (Range: 1-6)

Default Setting

A new trunk contains no ports.

Command Mode

Interface Configuration (Ethernet)

Command Usage

• When configuring static trunks, the switches must comply with

the Cisco EtherChannel standard.

• Use no channel-group to remove a port group from a trunk.
• Use no interfaces port-channel to remove a trunk from the

switch.

b_mgmt.book Page 178 Tuesday, July 8, 2003 5:24 PM