The RLM Manager program has now loaded the settings as identified in
the template file. Now you must change all the parameters that should
be unique to this Access Point RLM (see
)
prior to saving the configuration and returning to the main Radio Link
Module window by clicking
2.
.
5. Set the unique parameters that apply to this Access Point RLM.
The minimum set of unique parameters that you must set are listed in
Table 8 Unique RLM Parameters
.
6. Now save the configuration to the Access Point RLM, by clicking the
2.
button. You return to the main Radio Link Module window.
7.
Create a back-up file of the configuration for this Access Point RLM,
using the
'RZQORDG &RQILJ )LOH
command from the RLM menu.
Use a file name that allows you to easily recognize the relationship
between the file name and this Radio Link Module.
The entire set of common and unique parameters are now saved
permanently into the (non-volatile) FlashROM of the Access Point RLM.
They will remain stored in the RLM, even if the Radio Link Module is reset
or switched off and on again.
Repeat step 2 - 7 for every other Access Point RLM that you wish to
configure.