Siemens CP 1515 User Manual
Page 209
$GYDQFHG 3DUDPHWHUV
Industrial Ethernet Wireless LAN RLM Manager, CP 1515 Manager
C79000-G8976-C171-01
209
,3 DGGUHVV
Each Access Point RLM needs an unique IP address. Use either:
•
DHCP, to obtain an IP address automatically, or
•
manually enter an IP address
127(
i
All Access Point RLMs must have a unique IP address value to allow
you to address each Radio Link Module specifically. Duplicate IP
address values may cause unexpected behavior of the network and/
or negative impact on network performance.
0DQXDOO\ DVVLJQ DQ ,3 DGGUHVV
In case of manually assigning an IP address, use the field
$FFHVV 3RLQW ,3
$GGUHVV
to enter a value from the range of IP addresses assigned to your
organization.
The IP address is primarily used to address this Access Point RLM when you
use the RLM Manager program to configure and/or monitor this device.
When your organization does not use IP addressing, you can enter a user-
defined value. For example a value of the same pattern as the factory-set IP
address 153.69.254.254, where you replace the last three digits with a
numerical value in the range of “1” to “253”
.
$XWRPDWLFDOO\ DVVLJQ DQ ,3 DGGUHVV
In case when a DHCP server is available on the network, an IP address will
be automatically assigned to the Radio Link Module by the DHCP server. To
enable automatically obtaining an IP address form the DHCP server, select