Page 122

background image

(OLPLQDWLQJ 5HGXQGDQW 7UDIILF

122

Industrial Ethernet Wireless LAN RLM Manager, CP 1515 Manager

C79000-G8976-C171-01

Your network system will generate a large number of error messages as
a result of the faulty connection(s). As these messages are taking up
bandwidth, the performance of your network may become very slow.

&KHFNLQJ WKH &DEOH 6\VWHP

The occurrence of a problem in the cabling system can be diagnosed with
the remote statistics found on “Remote” tab in the monitor mode of the
RLM Manager.

1.

Select

,QWHUIDFH

(WKHUQHW

from the pull-down menu to display the

statistics for the Ethernet interface.

2. Compare the number of

,Q HUURUV

with the number of

%ULGJH LQ

SDFNHWV

.

When the number of “In errors” is 1% or more of the “Bridge in
packets”

, this may indicate a cabling problem.

3. Compare the number of packets

2XW HUURUV

with the number of

%ULGJH

RXW SDFNHWV

.

When the number of “Out errors” is 1% or more of the “Bridge out
packets”

, it is likely that there is a cabling problem.

4. Compare the number of

2XW FDUULHU VHQVH HUURUV

with the number of

%ULGJH RXW SDFNHWV

.

When the number of “Out carrier sense errors” is 1% of the
“Bridge out packets” or the value of the “Out carrier sense errors”
increases too rapidly, this indicates insufficient space on the
network due to a backbone overload, or faulty cabling.