2 snmp ip access list, Snmp ip access list – Siemens CP 1515 User Manual
Page 178
6HFXULQJ $FFHVV 3RLQW 5/0 6HWXS
178
Industrial Ethernet Wireless LAN RLM Manager, CP 1515 Manager
C79000-G8976-C171-01
5HDG:ULWH SDVVZRUG
A read/write password will provide you with full access to display Radio Link
Module diagnostic information found under the
0RQLWRU
button, as well as
the configuration settings found under the
(GLW
button.
Entering an incorrect password will result in a time-out error, or “SNMP error
no such name”
.
To define a read/write password:
1.
Start the RLM Manager and select the target RLM from the list or enter
a specific IP address.
2. Click the
(GLW
button to connect to the Radio Link Module.
3. Select the
6103
tab.
4. In the field
5HDG:ULWH 3DVVZRUG
, enter the new password. The
default value is “public”
.
5. Click
2.
to save the configuration to the Radio Link Module.
:$51,1*
!
7KH 5/0 ZLOO QRZ UHERRW
6103 ,3 $FFHVV /LVW
In addition to the read and read/write passwords, you can restrict access to
the Radio Link Module configuration to a limited number of authorized
stations.