beautypg.com

3 access point ip parameters, Access point ip parameters, Ffhvv srlqw ,3 3dudphwhuv – Siemens CP 1515 User Manual

Page 207

background image

$GYDQFHG 3DUDPHWHUV

Industrial Ethernet Wireless LAN RLM Manager, CP 1515 Manager
C79000-G8976-C171-01

207

$FFHVV SRLQW ,3 3DUDPHWHUV

The Access Point IP tab enables you to set the common IP parameters and
to change the unique IP address of your Radio Link Modules.

To change the IP parameters proceed as follows:

1.

Make sure you are connected to the right Access Point RLM in the edit
mode and select the

$FFHVV 3RLQW ,3

tab to display the IP parameters

(see

Figure 40 Setup Radio Link Module IP Parameters

).

2. Verify and/or modify the parameters of your choice.

The mandatory parameters that you must specify are:

$FHVV 3RLQW ,3

address (unique for each Access Point RLM, in

case of a BOOTP or DHCP server, this IP address is entered
automatically).

Access Point

6XEQHW 0DVN

(the same for all Radio Link Modules,

in case of a BOOTP or DHCP server, this IP address is entered
automatically).

(optional)

'HIDXOW URXWHU

(usually the same for all Access Point

RLMs.

(optional)

'HIDXOW 77/

(Time To Live) (usually the same for all

Access Point RLMs).

All parameters are explained in the next paragraphs.

3. When finished, proceed with configuring other parameters or click

2.

to save the configuration and return to the main RLM Manager window.