The Access Point IP tab enables you to set the common IP parameters and
to change the unique IP address of your Radio Link Modules.
To change the IP parameters proceed as follows:
1.
Make sure you are connected to the right Access Point RLM in the edit
mode and select the
$FFHVV 3RLQW ,3
tab to display the IP parameters
(see
Figure 40 Setup Radio Link Module IP Parameters
2. Verify and/or modify the parameters of your choice.
The mandatory parameters that you must specify are:
•
$FHVV 3RLQW ,3
address (unique for each Access Point RLM, in
case of a BOOTP or DHCP server, this IP address is entered
automatically).
•
Access Point
6XEQHW 0DVN
(the same for all Radio Link Modules,
in case of a BOOTP or DHCP server, this IP address is entered
automatically).
•
(optional)
'HIDXOW URXWHU
(usually the same for all Access Point
RLMs.
•
(optional)
'HIDXOW 77/
(Time To Live) (usually the same for all
Access Point RLMs).
All parameters are explained in the next paragraphs.
3. When finished, proceed with configuring other parameters or click
2.
to save the configuration and return to the main RLM Manager window.