$GYDQFHG 3DUDPHWHUV

Industrial Ethernet Wireless LAN RLM Manager, CP 1515 Manager
C79000-G8976-C171-01

211

The Default Router is also relevant if you want to manage (or just ping) the
Access Point RLM from an other subnet.

7LPH 7R /LYH 77/

The field

'HIDXOW 77/

(Time To Live) identifies the maximum number of

hops for an IP message generated by the Access Point RLM (typically used
for the trap host messages).

The value will be decreased each time the message passes a router. When
the TTL value becomes 0, the message will be rejected by the next router it
meets. By default, the value is 64.

6103 3DUDPHWHUV

Most SNMP parameters (except for the System Location and System Name)
are common parameters, i.e. they should be the same for ALL Radio Link
Modules in your network.

To set the SNMP parameters proceed as follows:

1.

Make sure you are connected to the right Access Point RLM and select
the

6103

tab to display the SNMP parameters pictured in

Figure

41 Setup SNMP parameters

.