Sync – Arturia KeyStep Pro Keyboard with Advanced Sequencer and Arpeggiator User Manual
Page 152
♪
: In a Project, each track can be configured to send on a specific channel. When you load the project
the Project settings overwrite the Global MIDI settings. Please refer to
for details about
this.
9.1.2. Sync
Sync
Values
Description
Input
Source
[Internal, USB, MIDI, Clock, Auto (d)]
Defines tempo and sync source
Clock
Rate
[1 PP16, 2 PPQ, 24PPQ (d), 48PPQ]
Allows you to choose from the different
analog clock rate types
Output
[1 PP16, 2 PPQ8, 1 PPQ, 1PP2Q, 1 PPQ4Q,
2PPQ, 24PPQ (d), 48PPQ]
Use these settings to sync KeyStep Pro to
various analog clock types
These settings allow you to specify the inputs for receiving synchronization and tempo
signals, as well as the input and output clock rates. By changing these settings, you
determine which type of clocking signal will be transmitted via the output connectors and
which type will be recognized by the sync/clock inputs.
Auto Mode works as follows:
• If no clock signal is received, you can set the tempo and press Play. The KeyStep
Pro will then behave as in Internal mode
• If Clock / MIDI Transport Control (MTC) is received, the external clock takes
priority over the internal clock. The resulting tempo is calculated based on the
external clock. When the external clock stops, the sequencers/arpeggiators stop
• If a MIDI Stop message is received, all running sequencers/arpeggiators will
stop.
The Sync Output submenu enables you to set the clock type for the analog output clock:
• 1PP16 = 1 pulse per 16th beat (clocked)
• 1PP8 = 1 pulse per 8th beat (1 pulse every two 1/16th beats)
• 1PPQ = 1 pulse per quarter beat
• 1PP2Q = 1 pulse per 2 quarter beats
• 1PP4Q = 1 pulse per 4 quarter beats
• 2PPQ = 2 pulses per quarter beat
• 24PPQ = 24 pulses per quarter beat
• 48PPQ = 48 pulses per quarter beat
146
Arturia - User Manual Keystep Pro - KeyStep Pro Configuration