Generac Power Systems MC User Manual
Page 51
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
When the Stop/Start Switch is set to STOP, Ignition Stator (IS) output
from Wire No. 25, Ignition Module (IM) Pin No. 3, Wire No. 25 to the
Terminal Block and Wire No. 20 is delivered to frame ground. Ignition
terminates and the engine shuts down. The Control Relay de-energizes
and its contacts open to close the Fuel Lockoff Solenoid (FS) and ter
minate Fuel Pump (FP) operation,
2.4.3-
DIAGNOSTIC TESTS
2.4.3.1-
CHOKE PULSE MODULE
METHOD 1:- Install a known good Choke Pulse Module, Crank engine,
RESULT:- Choke operates normally...........Replace Choke Pulse Module
Engine starts.
Choke does not function and/or....Continue Diagnostic Tests,
no start
Section 2,1
METHOD 2:- A.)-
Unplug Choke Pulse Module, Set VOM
to "+DC” and to ”50V." scale.
Connect positive (+) meter test
probe to Module receptacle Pin No,
1, common (-) test probe to frame
ground. Crank engine. Meter should
indicate 9-12 Volts DC. This is
the input voltage to the Choke Pu
lse Module,
Choke Pulse
Module
Ignition
Module ReceptacI
Choke Pulse
Module Receptacle-
B, )-Plug Choke Pulse Module into
its receptacle. Set VOM to ”+DC"
and to "50V,” scale. From bottom
of receptacle, connect positive (+)
meter test probe into receptacle
Pin No. 1 and common (-) test probe
to frame ground. Crank engine. The
meter should indicate a pulsing
voltage and choke solenoid should
pulse.
C. )-Plug Choke Pulse Module into its receptacle. Set VOM to "+DC" and
to '’50V,” scale. From bottom of Module receptacle, connect positive
meter test probe to receptacle Pin No. 3, Connect common (-) test pr
obe to frame ground. Crank engine. Meter should indicate approximate
ly 12 Volts DC.
RESULTS:-All tests were good..,.Continue diagnostic tests. Section 2.1
Test A checked bad.... Check Wire No. 90 between receptacle
and Choke Solenoid, Choke Solenoid,
Wire No, 91 between Choke Solenoid and
Starter Solenoid (SC), Starter Solenoid
(SC)
Test B checked bad.... Replace Choke Pulse Module (CM)
Test C checked bad,,,,.Replace Choke Pulse Module (CM)