TEST 26:- VALVES

Remove valves. Clean all parts in
non-flammable solvent. Remove all

carbon. Replace damaged or distor­
ted valves. If valves are useable,

lap them as outlined in engine se­
ction. Check for correct tappet

clearance as outlined in engine

section of manual.

Valve

Roller

Spring Retainer

Valve Spring

Valve Spring Retainer

Tappet

TEST 27:- RINGS

Check for broken or worn rings.
Check ring clearance-in piston

grooves and ring gap. Refer to
engine section of manual.

TEST 28:- CYLINDER

Inspect cylinder walls for burning, scoring, or scratching. Check cylin­
der inner diameter. Refer to engine section of manual for inspection

requirements.

TEST 29:- TIMING

The ignition magnet is retained to

the fan with a special adhesive

which is cured at 300°F. for 1 hour

(or 265°F. for 1% hours) after ins­
tallation. The ring gear is heated

and pressed over the fan and magnet
assembly. The entire assembly is

then balanced as a unit, and finall-

y heated and epoxied into place over
the rotor shaft. Any damage to the
Rotor, Fan, Magnet or Ring Gear is
cause for replacement of the entire
assembly.

This Pol« Must Attract Th«
North Soaking Poia Ot A

Magnatic Compass

Magnai

Location

astabilshas

Timing At 21* BTDC

2.2-14