Symdec / symsafe (dvr) 107, Symdec / symsafe (dvr) – Interlogix TruVision Navigator 5.0 User Manual User Manual
Page 115

Appendix A: Device Details
TruVision Navigator 5.0 Service Pack 3 User Manual
107
SymDec / SymSafe (DVR)
Feature Support
Notes
Default Ports
Video = 5858 for TCP or 8100 to 8115 for
UDP (editable)
Command and Control = 1024 (editable)
Configuration = 1024 (editable)
Notifications = 1027 (editable)
Firmware Upload = 1024 (editable)
Default Username /
Password
N/A
Compression MPEG4
Connection Types
Reverse TCP
Reverse TCP I-frame
UDP
Streaming Limits
32 Live and 16 Playback streams
simultaneously
This is however further restricted by the
bandwidth maximum of 32 * 3MB/sec.
Example: When all cameras are full D1
30FPS/ High quality (3MBs), you can
only have 32 streams (i.e. 16 Live, 16
Playback). When you change the frame
rate/resolution/quality to low (1MB/s), 32
Live+16 Playback can be achieved.
See Connection Manager and
Connection Priority.
Stream Overlay
Camera Name
Date and Time
Bit rate
Alarm Detection
High / Low Bandwidth
Yes
Low bandwidth is only I-frames.
High bandwidth is I and P-frames.
Dual Streaming
No
Stream Nomenclature
N/A