Figure 44 TC2201 LEDs

Power/fault

Ethernet Activity

iSCSI Activity

SCSI Activity for Bus 0 SCSI Activity for Bus 1

iSCSI Link Status

The LED functionality of the TC2201 is detailed below:

Power and Fault (Pwr)—This indicator is a bi-color LED. When green,

this indicator shows that power is currently active. Lack of power

indication suggests that the unit is turned off, a problem with the

power supplied to the unit, or an internal problem with the unit.

When this indicator is amber, this indicator shows that the TC2201

detects a fault condition. Faults can occur as a result of Power On Self

Test (POST) failure or operational failures. It is normal for this

indicator to flash on when the unit is powered up or reset. If the fault

indicator stays lit, contact your product support representative.

iSCSI (Lnk/Act)—When lit green, the upper indicator signifies a good

iSCSI link on the port. When lit green, the lower indicator signifies

iSCSI port activity. If the Link indicator fails to light at all, or if the

Activity indicator stays continually lit without corresponding SCSI

bus activity, there may be a problem with the iSCSI configuration.

Verify the iSCSI configuration.

SCSI Bus (0, 1)—When lit, these green indicators signify SCSI activity

on the bus corresponding to the number of the indicator. Activity

should be indicated only occur briefly during power up or

configuration, and relatively often when the unit is transferring data.

If an Activity indicator stays continually lit without corresponding

target device activity, there may be a problem with the SCSI bus

configuration. Verify the SCSI bus configuration.

Ethernet (10/100)—When lit, these green indicators signify Ethernet

link status and activity. If either of these indicators fail to flicker, or

stay continuously lit, there may be a problem with the network

connection or configuration. Verify the network connection and

configuration. The port must be connected to a 10/100BaseT Ethernet

network to function properly.