9.

Verify the drive operation by using the system utilities.

Use the iLO MP commands to verify operation.

Use the BCH commands to verify operation.

Use diagnostics provided by the offline diagnostic environment to exercise the newly
installed module.

Removing and Replacing Airflow Guides

You must remove airflow guides before installing processors or memory. The server has the
following airflow guides:

The processor airflow guide ensures that the proper volume of air for cooling the dual
processor module power pods, processor modules, and voltage regulator modules flows
over these components. You must remove the processor airflow guide before removing or
installing a dual processor module.

The memory airflow guide ensures that the proper volume of air flows over the memory
DIMMs to cool them. To access memory DIMMs and sockets, you must remove the memory
airflow guide.

NOTE:

Air flows through the server from front to back.

Figure 3-23 Airflow Guides Locations

Removing and Replacing the Memory Airflow Guide

Removing the Memory Airflow Guide

To remove the memory airflow guide, follow these steps:

1.

Power off the server and disconnect the power and external cables.

2.

Remove the server chassis cover. (See

“Removing and Replacing the Top Cover on a

Rack-Mounted Server” (page 53)

.)