To define ID number, control type and authentication mode
Using the
GV-AS120 Setting AP
in the GV-ASManager folder, you can define the ID
number of multiple GV-AS120 connected through RS-485 interface, as well as set the
control type and authentication mode.
1. Go to
C:\Access Control\ASManager\
and double-click
GV-AS120 SetupAP
V100.exe
. This dialog box appears.
Figure 3-7
2. Select the COM port that is connected to GV-AS120 and click
Open COM
. The red
square should change to blue to indicate the COM port is correct.
Note:
To verify the COM port that is connected to GV-AS120, go to Windows Device
Manager. In the Ports (COM & LPT) field, you should see the entry for
Prolific USB-to-
Serial Comm Port
. The COM port shown in parenthesis indicates the COM number
currently in use.
3. Select an ID number for the GV-AS120.
4. Use the drop-down list to define the
Control Type
and
Authentication Mode
. Refer to
Door / Gate Function
and
Set Authentication Mode
in
2.3.2 Programming the GV-AS110
for more details on each type of Control Type and Authentication Mode.
5. Click
Setup GO
. The settings are sent to GV-AS120.