B output condition settings – GeoVision GV-AS2120 IP Control Panel User Manual
Page 175

The Web Interface
173
8
=
4
7
8.2.7.B Output Condition Settings
This section explains the output functions available when
Output Type
is set to
Normal
,
Toggle
or
Pulse
.
Door/Gate/Relay Condition x 2
Input/Reader Condition x 2
Output Type
Figure 8-22
There can be a maximum of 4 conditions that can be set up to trigger an output. 2 conditions
are Door/Gate/Relay conditions and 2 conditions are Input/Reader conditions. Each
condition is related to each other through
AND/OR
.
AND
means that all conditions with
AND
must be triggered before the output is triggered.
OR
means that only 1 of the condition with
OR
is needed to be triggered before the output is triggered. It is also valid to have certain
conditions as
AND
and certain conditions as
OR
.
For
Pulse
output type, the output is triggered for the amount of time set in the
Sec
field
(seconds).