GeoVision GV-AS2120 IP Control Panel User Manual
Page 160

158
[Events]
Set the parameters for the events.
•
When
Door Control
is selected in
the
Function Configuration
page (Figure 8-8), these
options become available:
Option
Description
Anti-Passback
Enables or disables the Anti-Passback function.
Lock Reset Time
Sets the time (1 to 600 sec.) that a door remains open after which
the door will automatically be locked.
Held Open Time
Sets the time (5 to 9999 sec.) that a door can be held open before
an alarm is generated.
Fire Action
Locks or unlocks the door when a fire condition occurs. Otherwise,
remains the door’s current state by selecting
Unchanged
.
Alarm Continuous
Time
Sets the time (1 to 10 sec.) that the alarm will continuously go off
before it ends.
Note:
The Lock Reset Time of 1 to 600 seconds is only supported by GV-AS21 / 41 / 81
series Controller firmware V2.0 or later.
•
When
Parking Control
is selected in
the
Function Configuration
page (Figure 8-8),
these options become available:
Option
Description
Anti-Passback
See the same option above.
Relay On Time
Sets the time (1 to 255 sec.) that a gate remains open after which
the gate will automatically be closed.
Held Open Time
See the same option above.
Fire Action
Alarm Continuous
Time
•
When
Elevator Control
is selected in the
Function Configuration
page (Figure 8-8),
these options become available:
Option
Description
Relay on Time
See the same option above.
Fire Action
Alarm Continuous
Time
See the same option above.