GeoVision GV-AS2120 IP Control Panel User Manual
Page 171

The Web Interface
169
8
=
4
7
Input
Type
Input Function
Description
Door #
Fire Zone
Tamper Zone
Exit Button
Door Contact
Armed Status
Depending on the type of sensor and the
location where it is installed, select the most
suitable Input Function name to describe the
sensor. When the sensor is activated, an alarm
event may occur and it can also trigger alarms.
For the type of alarm, see [Alarm],
8.2.2
Parameter Configuration
.
For example, when the
Door Contact
sensor
detects unauthorized access, a “Force Open”
type of event occurs and the event may trigger
the “Force Open” alarm.
For more details on how Armed Status works,
refer to
Gate #
Fire Sensor
Tamper Zone
Exit Button
Car Detection
See the “Door #” Input Type above.
For example, when the Car Detection sensor
detects any car driving by, a “Park Entry” or
“Park Exit” type of event occurs and the parking
gate will respond the event accordingly.
Relay #
Fire Sensor
Tamper Zone
See the “Door #” Input Type above.
For example, the Tamper Zone sensor is
installed on GV-AS Controller. So whenever
there is any attempt to open the GV-AS
Controller’s cabinet, the “Tamper” type of event
occurs and the event may trigger the “Tamper”
alarm.
All Zone Fire Sensor
If All Zone is selected, the Input Function will
automatically be set to Fire Sensor. When
triggered, fire sensors on all doors associated
with that controller will be triggered.
Note:
For alarm outputs, the corresponding alarms must be enabled (YES) in the
Parameter Configuration
page (Figure 8-9). If alarms are set to be disabled (NO), then
the alarm function here will not work when triggered.